Balcon, Manuel (2013) Geometrical metrology at micro scale: new approach and application to microfluidic devices. [Tesi di dottorato]

Full text disponibile come:

[img]
Anteprima
Documento PDF - Versione sottomessa
4Mb

Abstract (inglese)

About 30 years ago, in the industry for the production of semiconductors, started the race for the reduction of the dimensions of several electronic components. The trend followed the well-known Moore’s law and the dimensions of the chips halved every 18 months. The effect of reduction of the dimensions of products and components involved other scientific and technological fields. Products with micrometric dimensions, i.e. with one fundamental dimension in the range of micrometres, are presents in different domains including mechanics, biology, physics and medicine. The micro engineering concerns with the design, the realization and the industrialization of these products with micrometric dimensions. A fundamental phase of micro engineering is product/process quality control and related measurements. The metrology at micro scale is part of the manufacturing chain of micro products during the design, with the definition of the specifications, during the manufacturing, for the control of the process and in the final phase for the verification of specifications. The measurement of the dimensions and geometries at micrometric level is nowadays in evolution: several aspects, including the development of instruments and measurement techniques, need more studies.
The thesis here presented wants to contribute increasing the knowledge in the field of micro metrology and to provide useful solutions to improve the dimensional and geometrical characterization of micro products.
Although, the research has been developed to be valid in general, it is included as an integral part of the European project “CellDiaSp”. The project, in collaboration with international partners, provides for the realization of a microfluidic platform for cells analysis.
The metrological activities, required by the project, are needed to characterize the dimensions and the geometry of prototypes, mould inserts, masters and finite products, in order to guarantee the respect of the specifications and the functionality of the final product.
The first phase of the research deals with the study of the state of the art of metrology and of the relevant measurement techniques that can be used at micro scale.
Successively the application of some of these techniques to the replication processes has been studied. These processes, such as micro injection moulding, are used to obtain mass production and a cost reduction. It has been considered the possibility to measure the components presents in the process of replication, that is the inserts and the replicated parts and to evaluate the quality of the replication process through the calculation of single parameters such as parameters used in the measurement of surfaces. It resulted that this is possible only in few specific cases and that it is preferable to perform a complete three dimensional characterization of the dimensions and geometries of the product of replication.
It has been decided to focus the attention on two typologies of instruments: the scanning probe microscopes and the optical profilometers. These instruments are adapted to the measurement of the parts to be investigated within the project and, moreover, they are the best candidates to be implemented as coordinate measuring instruments, even if they were originally developed as surface measurement instruments.
The problem of “drift”, an effect that reduces the accuracy of the measurements performed through atomic force microscopes, has been treated. The causes of the phenomenon have been identified and solutions to the reduction of this error have been provided.
In order to obtain coordinate measurements from the atomic force microscopes and from the optical profilometer, a new technique for the data analysis has been developed.
The new methodology is presented applied to a case study of a microfluidic channel measured through optical profilometry. The technique is inspired by the international standards in the field of geometrical product specification and verification, with particular reference to coordinate metrology. However, these standards can’t be directly applied to product with micrometric dimensions and they require new solutions for the analysis of the data. A dedicated software has been developed to treat the data, acquired through a confocal microscope, both as image and as point cloud, taking advantage of both approaches and related representation. Specific procedures of filtration and thresholding have been developed to perform the extraction of the points and the association of the geometrical features for the evaluation of dimensions and geometries of the sample. The developed software provides a semi-automatic and repeatable way for the coordinate measurement of micrometric components.
Finally, the developed technique has been validated using a case study: the measurements of microfluidic channels with cylindrical section used in the realization of peristaltic pumps.

Abstract (italiano)

Circa 30 anni fa, nell’industria per la produzione di semiconduttori, iniziò la corsa alla riduzione delle dimensioni di vari componenti elettronici. L’andamento seguì la famosa legge di Moore ed è stato possibile assistere, ogni 18 mesi circa, ad un dimezzamento delle dimensioni dei chip. L’effetto di riduzione della dimensione di prodotti e componenti ha coinvolto, sebbene in modo meno evidente, anche altri campi scientifici e tecnologici. Prodotti di dimensioni micrometriche, cioè in cui una dimensione fondamentale del prodotto è mille volte inferiore rispetto ad un millimetro, sono presenti nella meccanica, nella biologia, nella fisica e in ambito medico. La microingegneria si occupa della progettazione, realizzazione e industrializzazione di questi prodotti di dimensioni micrometriche. Una fase fondamentale della microingegneria è il controllo di qualità. La metrologia in ambito micrometrico entra nella catena produttiva dei microprodotti durante la progettazione, con la definizione delle specifiche, durante la produzione, per il controllo del processo, e nella fase finale, per la verifica del rispetto delle specifiche.
La misura delle dimensioni e delle geometrie a livello micrometrico è tuttora in evoluzione: numerosi aspetti, tra cui lo sviluppo di strumenti e tecniche di misura adeguate, necessitano di approfondimento.
Il lavoro di tesi di seguito presentato vuole contribuire all’aumento delle conoscenze in ambito metrologico micrometrico e vuole fornire soluzioni utili a migliorare la caratterizzazione dimensionale e geometrica dei prodotti.
Sebbene la ricerca sia stata sviluppata per essere valida a livello generale, essa rientra nell’ambito del progetto europeo “CellDiaSp”. Il progetto prevede, in collaborazione con partner internazionali, la realizzazione di una piattaforma microfluidica per l’analisi cellulare. Le attività metrologiche richieste dal progetto servono per caratterizzare le dimensioni e la geometria dei prototipi, degli inserti di stampi e dei prodotti finiti, garantendo il rispetto delle specifiche e quindi la funzionalità del prodotto finito.
La prima fase della ricerca ha riguardato lo studio dello stato dell’arte della metrologia e delle principali tecniche di misura applicabili a livello micrometrico, delle loro caratteristiche e dei loro limiti.
Successivamente è stata studiata l’applicazione di alcune di queste tecniche ai processi di replicazione. Tali processi, come ad esempio il microstampaggio ad iniezione, sono necessari per ottenere una produzione di massa dei prodotti e ridurne quindi il costo. È stata considerata la possibilità di misurare le varie parti presenti nel processo di replicazione, ovvero gli inserti degli stampi e i prodotti replicati, e di valutare la qualità del processo tramite singoli parametri, come ad esempio parametri di misura della superficie. Dallo studio è emerso che questo è possibile solo in alcuni casi specifici e che è preferibile avere una caratterizzazione tridimensionale completa delle varie dimensioni e geometrie del prodotto replicato.
Si è quindi deciso di concentrare l’attenzione su due tipologie di strumenti: i microscopi a scansione di sonda e i profilometri ottici. Questi strumenti sono adatti alla misura dei componenti previsti dal progetto e sono inoltre i candidati migliori per essere sviluppati nell’ambito della misura a coordinate, sebbene nascano per la misura delle superfici.
È stato trattato il problema della “deriva”, un effetto che riduce l’accuratezza delle misure effettuate con microscopi a forza atomica. Sono state indagate le cause di questo fenomeno in diverse configurazioni commerciali di strumenti e sono state fornite le soluzioni per la riduzione di questo errore.
Al fine di ottenere misure a coordinate dai microscopi a forza atomica e dai profilometri ottici, è stata sviluppata una nuova tecnica di analisi dei dati di misura. La nuova metodologia viene presentata applicata al caso studio di un canale microfluidico misurato con profilometria ottica.
La tecnica prende ispirazione da quanto previsto dalle norme internazionali in ambito di metrologia a coordinate. Tali norme, tuttavia, non possono essere direttamente applicate a prodotti di dimensioni micrometriche e richiedono accorgimenti nel trattamento dei dati. È stato quindi creato un codice di calcolo, che sfruttando la natura dei dati di misura ottenuti, ad esempio da un microscopio confocale, li tratta sia come immagine sia come nuvola di punti. Sono state sviluppate procedure specifiche di filtraggio e sogliatura, al fine di effettuare l’estrazione dei punti e l’associazione con elementi geometrici per la valutazione delle dimensioni e della geometria del campione in oggetto. Il codice di calcolo realizzato fornisce un modo semi automatico e ripetibile per la misura di componenti micrometrici.
Infine, la tecnica sviluppata è stata utilizzata per la misura delle dimensioni di canali microfluidici a sezione cilindrica utilizzati nella realizzazione di pompe peristaltiche.

Statistiche Download - Aggiungi a RefWorks
Tipo di EPrint:Tesi di dottorato
Relatore:Bariani, Paolo
Dottorato (corsi e scuole):Ciclo 25 > Scuole 25 > INGEGNERIA INDUSTRIALE > INGEGNERIA DELLA PRODUZIONE INDUSTRIALE
Data di deposito della tesi:29 Gennaio 2013
Anno di Pubblicazione:29 Gennaio 2013
Parole chiave (italiano / inglese):microfluidic, coordinate metrology, micro, optical profilometry, surface, metrology
Settori scientifico-disciplinari MIUR:Area 09 - Ingegneria industriale e dell'informazione > ING-IND/16 Tecnologie e sistemi di lavorazione
Struttura di riferimento:Dipartimenti > Dipartimento di Ingegneria Industriale
Codice ID:5677
Depositato il:15 Ott 2013 11:11
Simple Metadata
Full Metadata
EndNote Format

Bibliografia

I riferimenti della bibliografia possono essere cercati con Cerca la citazione di AIRE, copiando il titolo dell'articolo (o del libro) e la rivista (se presente) nei campi appositi di "Cerca la Citazione di AIRE".
Le url contenute in alcuni riferimenti sono raggiungibili cliccando sul link alla fine della citazione (Vai!) e tramite Google (Ricerca con Google). Il risultato dipende dalla formattazione della citazione.

[1] H.N. Hansen, K. Carneiro, H. Haitjema, L. De Chiffre, (2006), "Dimensional micro and nano metrology", CIRP Annals - Manufacturing Technology, 55, 721–743. Cerca con Google

[2] K.J. Stout, (1998), "From cubit to nanometre - a history of precision measurement", Press, Penton. Cerca con Google

[3] L. Alting, F. Kimura, H.N. Hansen, G. Bissacco, (2003), "Micro engineering", CIRP Annals - Manufacturing Technology, 52, 635–657. Cerca con Google

[4] G. Bissacco, (2004), "Surface generation and optimization in micromilling", Ph.D.Thesis, Supervised by Prof. Leonardo De Chiffre, Technical University of Denmark. Cerca con Google

[5] A. Weckenmann, T. Wiedenhoefer, (2005), "The use of the GPS-Standard in Nanometrology", Proc. of 5th euspen international conference, pp. 169–172, Montpellier, France. Cerca con Google

[6] P. Bariani, (2005), "Dimensional Metrology for Microtechnology", Ph.D.Thesis, Supervised by Prof. Leonardo De Chiffre and Prof. Hans N. Hansen, Technical University of Denmark. Cerca con Google

[7] M. Reilly, S P, Leach, R K, Cuenat, A, Awan, S A, Lowe, (2008), "NPL REPORT DEPC-EM 008 - Overview of MEMS sensors and the metrology requirements for their manufacture". Cerca con Google

[8] G. Rodger, (2001), "Measurement Good Practice Guide nr. 39 - Dimensional Measurements using Vision Systems", NPL - National Physical Laboratory, Teddington (UK). Cerca con Google

[9] A. Voltan, (2010), "Metrological performance verification of optical coordinate measuring systems", Ph.D.Thesis, Supervised by Prof. Enrico Savio, Università degli Studi di Padova. Cerca con Google

[10] F. Marinello, P. Bariani, E. Savio, A. Horsewell, L. De Chiffre, (2008), "Critical factors in SEM 3D stereo microscopy", Measurement Science and Technology, 19, art. n. 65705. Cerca con Google

[11] L. Carli, (2010), "3D-SEM metrology for coordinate measurements at the nanometer scale", Ph.D.Thesis, Supervised by Prof. Leonardo De Chiffre, Technical University of Denmark. Cerca con Google

[12] F. Marinello, (2007), "Atomic force microscopy in nanometrology: modeling and enhancement of the instrument", Ph.D.Thesis, Supervised by Prof. Paolo F. Bariani and Prof. Leonardo DE Chiffre, Università degli Studi di Padova. Cerca con Google

[13] (2011), ISO 17450-1:2011 Geometrical product specifications (GPS) -- General concepts -- Part 1: Model for geometrical specification and verification, Iso, Geneva. Cerca con Google

[14] G. Tosello, H.N. Hansen, F. Marinello, S. Gasparin, (2010), "Replication and dimensional quality control of industrial nanoscale surfaces using calibrated AFM measurements and SEM image processing", CIRP Annals-Manufacturing Technology, 59, 563–568. Cerca con Google

[15] G. Tosello, H.N. Hansen, S. Gasparin, (2009), "Applications of dimensional micro metrology to the product and process quality control in manufacturing of precision polymer micro components", CIRP Annals - Manufacturing Technology, 58, 467–472. Cerca con Google

[16] R.K. Leach, (2010), "Fundamental principles of engineering nanometrology", William Andrew, Elsevier, 1st ed. Cerca con Google

[17] (2012), ISO 25178-2:2012 Geometrical product specifications (GPS) -- Surface texture: Areal -- Part 2: Terms, definitions and surface texture parameters, Iso, Geneva. Cerca con Google

[18] P. Pawlus, L. Galda, A. Dzierwa, W. Koszela, (2009), "Abrasive wear resistance of textured steel rings", Wear, 267, 1873–1882. Cerca con Google

[19] T. V Vorburger, J.F. Song, W. Chu, L. Ma, S.H. Bui, A. Zheng, et al., (2011), "Applications of cross-correlation functions", Wear, 271, 529–533. Cerca con Google

[20] B. Mokaberi, A.A.G. Requicha, (2004), "Towards automatic nanomanipulation: drift compensation in scanning probe microscopes", Proc. of ICRA 04 International Conference on Robotics and Automation, pp. 416–421, Barcelona, Spain. Cerca con Google

[21] A.A.G. Bruzzone, H.L. Costa, P.M. Lonardo, D.A. Lucca, (2008), "Advances in engineered surfaces for functional performance", CIRP Annals - Manufacturing Technology, 57, 750–769. Cerca con Google

[22] H.N. Pishkenari, N. Jalili, A. Meghdari, (2006), "Acquisition of high-precision images for non-contact atomic force microscopy", Mechatronics, 16, 655–664. Cerca con Google

[23] F. Marinello, P. Bariani, S. Carmignato, E. Savio, (2009), "Geometrical modelling of scanning probe microscopes and characterization of errors", Measurement Science and Technology, 20, art. no 84013. Cerca con Google

[24] H.J. Hug, T. Jung, H.J. Guntherodt, (1992), "A high stability and low drift atomic force microscope", Review of scientific instruments, 63, 3900–3904. Cerca con Google

[25] F. Marinello, P. Bariani, L. De Chiffre, E. Savio, (2007), "Fast technique for AFM vertical drift compensation", Measurement Science & Technology, 18, 689–696. Cerca con Google

[26] B. Sahu, C.R. Taylor, K.K. Leang, (2010), "Emerging challenges of microactuators for nanoscale positioning, assembly, and manipulation", Journal of Manufacturing Science and Engineering, 132, 1–16. Cerca con Google

[27] Y. Zhao, D.L. Trumper, R.K. Heilmann, M.L. Schattenburg, (2010), "Optimization and temperature mapping of an ultra-high thermal stability environmental enclosure", Precision Engineering, 34, 164–170. Cerca con Google

[28] M.A. Donmez, M.H. Hahn, J.A. Soons, (2007), "A novel cooling system to reduce thermally-induced errors of machine tools", CIRP Annals-Manufacturing Technology, 56, 521–524. Cerca con Google

[29] H. Schwenke, W. Knapp, H. Haitjema, A. Weckenmann, R. Schmitt, F. Delbressine, (2008), "Geometric error measurement and compensation of machines - an update", CIRP Annals-Manufacturing Technology, 57, 660–675. Cerca con Google

[30] D. Huo, K. Cheng, F. Wardle, (2010), "A holistic integrated dynamic design and modelling approach applied to the development of ultraprecision micro-milling machines", International Journal of Machine Tools and Manufacture, 50, 335–343. Cerca con Google

[31] F. Marinello, E. Savio, P. Bariani, S. Carmignato, (2009), "Coordinate metrology using scanning probe microscopes", Measurement Science and Technology, 20, art. n. 84002. Cerca con Google

[32] E. Savio, F. Marinello, P. Bariani, S. Carmignato, (2007), "Feature-Oriented Measurement Strategy in Atomic Force Microscopy", CIRP Annals - Manufacturing Technology, 56, 557–560. Cerca con Google

[33] B. Bhikkaji, S. Moheimani, (2009), "Fast scanning using piezoelectric tube nanopositioners: A negative imaginary approach", Proc. of AIM 2009 International Conference on Advanced Intelligent Mechatronics, pp. 274–279, Singapore. Cerca con Google

[34] D. Kang, K. Kim, D. Kim, J. Shim, D.G. Gweon, J. Jeong, (2009), "Optimal design of high precision XY-scanner with nanometer-level resolution and millimeter-level working range", Mechatronics, 19, 562–570. Cerca con Google

[35] G. Schitter, P.J. Thurner, P.K. Hansma, (2008), "Design and input-shaping control of a novel scanner for high-speed atomic force microscopy", Mechatronics, 18, 282–288. Cerca con Google

[36] H.S. Kim, Y.M. Cho, (2009), "Design and modeling of a novel 3-DOF precision micro-stage", Mechatronics, 19, 598–608. Cerca con Google

[37] K.K. Leang, S. Devasia, (2006), "Design of hysteresis-compensating iterative learning control for piezo-positioners: Application to atomic force microscopes", Mechatronics, 16, 141–158. Cerca con Google

[38] S. Kuiper, G. Schitter, (2010), "Active damping of a piezoelectric tube scanner using self-sensing piezo actuation", Mechatronics, 20, 656–665. Cerca con Google

[39] A. Mesbah-Nejad, M. Moallem, (2010), "A new actuation mechanism for an Interfacial Force Microscope: Design, implementation, and feedback control", Mechatronics, 20, 640–647. Cerca con Google

[40] Noliac A/S, www.noliac.com, as it is on December 2012. Vai! Cerca con Google

[41] D. Thomas, D.D. Ebenezer, S.M. Srinivasan, (2010), "Power dissipation and temperature distribution in piezoelectric ceramic slabs", The Journal of the Acoustical Society of America, 128, 1700–1711. Cerca con Google

[42] Image Metrology A/S, www.imagemet.com, plugin for SPIP, as it is December 2012. Vai! Cerca con Google

[43] J. Sirohi, I. Chopra, (2000), "Fundamental understanding of piezoelectric strain sensors", Journal of Intelligent Material Systems and Structures, 11, 246–257. Cerca con Google

[44] Y. Kurisaki, H. Sawano, H. Yoshioka, H. Shinno, (2010), "A newly developed XY planar nano-motion table system with large travel ranges", Journal of Advanced Mechanical Design, Systems, and Manufacturing, 4, 976–984. Cerca con Google

[45] M. Lu, S. Gao, Q. Jin, J. Cui, H. Du, H. Gao, (2007), "An atomic force microscope head designed for nanometrology", Measurement Science and Technology, 18, 1735. Cerca con Google

[46] H.U. Danzebrink, L. Koenders, G. Wilkening, A. Yacoot, H. Kunzmann, (2006), "Advances in scanning force microscopy for dimensional metrology", CIRP Annals-Manufacturing Technology, 55, 841–878. Cerca con Google

[47] P. Rahe, R. Bechstein, A. Kühnle, (2010), "Vertical and lateral drift corrections of scanning probe microscopy images", Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures, 28, C4E31. Cerca con Google

[48] F. Marinello, M. Balcon, S. Carmignato, E. Savio, (2011), "Long term thermal drift study on SPM scanners", Mechatronics, 21, 1272–1278. Cerca con Google

[49] A.A. Kuijpers, R.J. Wiegerink, G.J.M. Krijnen, T.S.J. Lammerink, M. Elwenspoek, (2004), "Capacitive long-range position sensor for microactuators", 17th IEEE International Conference on Micro Electro Mechanical Systems, pp. 544–547, Maastricht, Netherlands. Cerca con Google

[50] V. Studer, G. Hang, A. Pandolfi, M. Ortiz, W.F. Anderson, S.R. Quake, (2004), "Scaling properties of a low-actuation pressure microfluidic valve", Journal of Applied Physics, 95, 393–398. Cerca con Google

[51] M.A. Unger, H.-P. Chou, T. Thorsen, A. Scherer, S.R. Quake, (2000), "Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography", Science, 288, 113–116. Cerca con Google

[52] R.K. Leach, (2011), "Optical Measurement of Surface Topography", Springer, 1st ed. Cerca con Google

[53] Sensofar-Tech S.L., www.sensofar.com, as it is on December 2012. Vai! Cerca con Google

[54] R.C. Gonzalez, R.E. Woods, (2008), "Digital Image Processing", Prentice Hall, 3rd ed. Cerca con Google

[55] NPL National Physical Laboratory, www.eurometros.org, LSGE lscylinder MatLab routine to find least-square fit of cylinder to data, as it is on December 2012. Vai! Cerca con Google

[56] (2010), ISO 25178-6 Geometrical product specifications (GPS) -- Surface texture: Areal -- Part 6: Classification of methods for measuring surface texture, Iso, Geneva. Cerca con Google

[57] (2010), ISO 25178-602 Geometrical product specifications (GPS) -- Surface texture: Areal -- Part 602: Nominal characteristics of non-contact (confocal chromatic probe) instruments, Iso, Geneva. Cerca con Google

[58] X. Jiang, P.J. Scott, D.J. Whitehouse, L. Blunt, (2007), "Paradigm shifts in surface metrology. Part II. The current shift", Proceedings of the Royal Society A: Mathematical, Physical and Engineering Sciences, 463, 2071–2099. Cerca con Google

[59] L. Blunt, S. Xiao, (2011), "The use of surface segmentation methods to characterise laser zone surface structure on hard disc drives", Wear, 271, 604–609. Cerca con Google

[60] N. Senin, L. Blunt, M. Tolley, (2012), "The use of areal surface topography analysis for the inspection of micro-fabricated thin foil laser targets for ion acceleration", Measurement Science and Technology, 23, art. n. 105004. Cerca con Google

[61] J.P. Kruth, M. Bartscher, S. Carmignato, R. Schmitt, L. De Chiffre, A. Weckenmann, (2011), "Computed tomography for dimensional metrology", CIRP Annals - Manufacturing Technology, 60, 821–842. Cerca con Google

[62] S. Carmignato, (2012), "Accuracy of industrial computed tomography measurements: Experimental results from an international comparison", CIRP Annals - Manufacturing Technology, 61, 491–494. Cerca con Google

[63] J. Wang, X. Jiang, L.A. Blunt, R.K. Leach, P.J. Scott, (2012), "Intelligent sampling for the measurement of structured surfaces", Measurement Science and Technology, 23, art. n. 85006. Cerca con Google

[64] J. Wang, X. Jiang, L.A. Blunt, R.K. Leach, P.J. Scott, (2011), "Efficiency of adaptive sampling in surface texture measurement for structured surfaces", Journal of Physics: Conference Series, 311, art. n. 12017. Cerca con Google

[65] H.N. Hansen, G. Tosello, S. Gasparin, L. De Chiffre, (2011), "Dimensional metrology for process and part quality control in micro manufacturing", International Journal of Precision Technology, 2, 118–135. Cerca con Google

Download statistics

Solo per lo Staff dell Archivio: Modifica questo record