Vai ai contenuti. | Spostati sulla navigazione | Spostati sulla ricerca | Vai al menu | Contatti | Accessibilità

| Crea un account

Pasqualetto, Michele (2013) Sistema di monitoraggio energetico di edifici. [Tesi di dottorato]

Full text disponibile come:

[img]
Anteprima
Documento PDF - Versione pubblicata
4Mb

Abstract (inglese)

The project developed during the PhD period aims to design, develop, implement and verify an innovative system of sensors and algorithms of data processing, which makes it possible for an accurate survey and assessment of the main environmental and energy parameters in buildings.
The work has been included in the project SIMEA (Integrated/Distributed Energy Monitoring and Environmental), funded by the Region of Veneto in the "Strategic Plan for Scientific Research, Technological Development and Innovation 2008-2010".
The sensor system is designed to produce the energy/operating building profile to be used for:
- the purpose of certification of buildings;
- the process of energy audits to improve the working conditions and comfort;
- to promote the maximization of resources through an intelligent automatic control.
The theory concerning the energy efficiency of buildings is based on a compromise between comfort and consumption and, in fact, all the regulations are aimed to decrease (decrease) the power consumption without compromising the comfort of the internal environment in which people are living.
For this purpose, in the project of thesis have been considered, among others, UNI EN 15251:2007 which has the purpose to define which are the components to ensure the indoor comfort and UNI EN 15603:2008 which explains in detail the types of energy certifications. The sensor system developed is based on the latter regulation.
The technical literature presents several studies aimed at defining the effective energy assessment of the building and if it can be certified with a methodology based on performing calculations or measurements made in situ. It can be concluded that the procedures are not discriminating but complementary: methods of calculation are used for an assessment of the standard type, implemented by software tools, while the monitoring system are used for assessment of the real consumption.
The sensor system developed tries to satisfy the need to use a methodology based on monitoring the real behavior of building-plant but supported, for assessment of the energy consumption, by a calculation software validated at international level.
The hardware part of the monitoring system is formed by a series of sensors for the measurement of various thermohygrometric parameters and is divided into two networks that differ by type and objectives: the structure in the fixed network (wired) and the structure in the mobile network (wireless).
The development of the PhD project made it possible for monitoring with the system of sensors installed; this system permits not only the calculation of current consumption but also to define a short-term forecasts for the next day. In particular, the forecasts have been carried out in two modes:
- estimation of consumption with air conditioning on and the setpoint temperature;
- estimation of the temperature in free evolution with the conditioning system off.
The final part of the work was devoted to the validation of the predictions made and the use of the sensor network for other purposes that could expand the potential of the monitoring system developed.

Abstract (italiano)

Il lavoro sviluppato nell’ambito del dottorato di ricerca ha l’obiettivo di progettare, sviluppare, realizzare e verificare un sistema innovativo di sensori, e relativi algoritmi di elaborazione dei dati, che permetta di effettuare una rilevazione e una valutazione precise dei principali parametri ambientali ed energetici negli edifici.
Il progetto è stato inserito all’interno di un progetto sovvenzionato dalla Regione Veneto nell’ambito del “Piano strategico per la ricerca scientifica, lo sviluppo tecnologico e l'innovazione 2008-2010” denominato SIMEA (Sistema Integrato/distribuito di Monitoraggio Energetico ed Ambientale).
La rete di sensori ha lo scopo di produrre il profilo energetico/operativo dell’edificio per essere successivamente utilizzato:
- ai fini della certificazione, per elaborare degli audit energetici in modo da migliorare le condizioni operative e di comfort;
- per incentivare l’utilizzo ottimizzato delle risorse attraverso un controllo automatico intelligente;
- per ricavare informazioni utili alle procedure di manutenzione.
La teoria riguardante l’energetica degli edifici si basa sul sottile compromesso tra comfort e consumi e, infatti, tutte le normative sono volte a cercare di abbassare i consumi non compromettendo il comfort dell’ambiente interno dentro cui le persone vivono.
A questo scopo, nel lavoro di tesi sono state considerate, tra le altre, la norma UNI EN 15251:2007 che definisce quali sono le componenti per assicurare il comfort indoor e la UNI EN 15603:2008 che specifica le tipologie di certificazione energetica; ed è proprio a quest’ultima che si riferisce il sistema di sensori sviluppato.
La letteratura tecnica presenta numerosi studi volti a definire l’effettiva valutazione energetica di un edificio e se questa possa essere certificata con una metodologia basata su esecuzione di calcoli oppure su misure eseguite in loco. Si può concludere che i procedimenti non sono discriminanti ma complementari: i metodi di calcolo servono per una valutazione di tipo standard, implementata spesso da strumenti software, mentre i monitoraggi sono utilizzati per una valutazione reale dei consumi.
Il sistema di sensori sviluppato cerca di soddisfare l’esigenza di utilizzare una metodologia basata sullo sfruttamento dei monitoraggi per la valutazione ad hoc del comportamento reale edificio-impianto ma supportato, per la valutazione del consumo energetico, da un software di calcolo validato a livello internazionale.
La parte hardware del sistema di monitoraggio è formata da una serie di sensori per la misura delle varie grandezze termoigrometriche ed è diviso in due reti che differiscono per tipologia e obiettivi: la struttura a rete fissa, cablata, e la struttura a rete mobile, wireless.
Lo sviluppo del progetto di dottorato ha permesso di utilizzare i monitoraggi eseguiti con il sistema di sensori installato, non solo per il calcolo dei consumi attuali ma per realizzare anche delle previsioni a breve termine, ovvero per il giorno successivo. In particolare le previsioni effettuate sono state eseguite in due modalità:
- stima dei consumi con impianto di climatizzazione acceso e temperatura di setpoint impostata;
- stima della temperatura in evoluzione libera con impianto spento.
La parte conclusiva del lavoro è stata dedicata alla validazione delle previsioni eseguite nonché all’utilizzo della rete di sensori per altri scopi che potessero ampliare le potenzialità della sistema di monitoraggio sviluppato.

Statistiche Download - Aggiungi a RefWorks
Tipo di EPrint:Tesi di dottorato
Relatore:Zecchin, Roberto
Dottorato (corsi e scuole):Ciclo 25 > Scuole 25 > INGEGNERIA INDUSTRIALE > FISICA TECNICA
Data di deposito della tesi:27 Febbraio 2013
Anno di Pubblicazione:27 Febbraio 2013
Parole chiave (italiano / inglese):sistema di monitoraggio/monitoring system, rete di sensori/network of sensors, certificazione energetica degli edifici/energy certification of buildings.
Settori scientifico-disciplinari MIUR:Area 09 - Ingegneria industriale e dell'informazione > ING-IND/10 Fisica tecnica industriale
Struttura di riferimento:Dipartimenti > Dipartimento di Ingegneria Industriale
Codice ID:6070
Depositato il:21 Ott 2013 11:40
Simple Metadata
Full Metadata
EndNote Format

Bibliografia

I riferimenti della bibliografia possono essere cercati con Cerca la citazione di AIRE, copiando il titolo dell'articolo (o del libro) e la rivista (se presente) nei campi appositi di "Cerca la Citazione di AIRE".
Le url contenute in alcuni riferimenti sono raggiungibili cliccando sul link alla fine della citazione (Vai!) e tramite Google (Ricerca con Google). Il risultato dipende dalla formattazione della citazione.

Articoli all’interno di rivista Cerca con Google

Aguiar R., Oliveira M., Goncalves H., Climate change impacts on the thermal performance of Portuguese buildings. Results of the SIAM study, Building Services Engineering Research and Technology, 23(4)(2002), pp. 223-231. Cerca con Google

Amjady N., Short-term hourly load forecasting using time-series modeling with peak load estimation capability, IEEE Transactions on Power Systems, 16(3)(2001), pp. 498–555. Cerca con Google

Audenaert A., Briffaerts K., Engels L., Practical versus theoretical domestic energy consumption for space heating, Energy Policy, 39(2011), pp. 5219-5227. Cerca con Google

Ballarini I., Corrado V., Application of energy rating methods to the existing building stock: analysis of some residential buildings in Turin, Energy and Buildings, 41(2009), pp. 790-800. Cerca con Google

Bonarini A., Sistemi fuzzy, Mondo digitale, 1(2003), pp. 3-14. Cerca con Google

Brager G.S., de Dear R.J., Thermal adaptation in the built environment: a literature review, Energy and Buildings, 27(1)(1998), pp. 83-96. Cerca con Google

Branco G., Lachal B., Gallinelli P., Weber W., Predicted versus observed heat consumption of a low Energy multifamily complex in Switzerland based on long-term experimental data, Energy and Buildings, 36(2004), pp. 543-555. Cerca con Google

Brown N., Wright A.J., Shikla A., Stuart G., Longitudinal analysis of energy metering data from non-domestic buildings, Building Research and Information, 38(1)(2010), pp. 80-91. Cerca con Google

Burge C.A., Sick building syndrome, Occupational and Environmental Medicine, 61(2004), pp. 185-190. Cerca con Google

Caldera M., Corgnati S.P., Filippi M., Energy demand for space heating through a statistical approach: application to residential buildings, Energy and Buildings, 40(2008), pp. 1972-1983. Cerca con Google

Casari P., Castellani A.P., Cenedese A., Lora C., Rossi M., Schenato L., Zorzi M., The “Wireless Sensor Networks for City-Wide Ambient Intelligence (WISE-WAI)” Project, Sensors, 9(2009), pp. 4056-4082. Cerca con Google

Chen D., Wang X., Ren Z., Selection of climatic variables and time scales for future weather preparation in building heating and cooling energy prediction, Energy and Buildings, 51(2012), pp. 223-233. Cerca con Google

Dall’O’ G., Sarto, L., Galante A., Pasetti G., Comparison between predicted and actual Energy performance for winter heating in high-performance residential buildings in the Lombardy region (Italy), Energy and Buildings, 47(2012), pp. 247-253. Cerca con Google

de Dear R.J., Brager G.S., Thermal comfort in naturally ventilated buildings: revisions to ASHRAE Standard 55, Energy and Buildings, 34(6)(2002), pp. 549-561. Cerca con Google

Dodoo A., Gustavsson L., Sathre R., Building energy-efficiency standards in a life cycle primary energy perspective, Energy and Buildings, 43(2011), pp. 1589-1597. Cerca con Google

Emery A.F., Kippenhan C.J., A long term of residential home heating consumption and the effect of occupant behavior on homes in the Pacific Northwest constructed according to improved thermal standards, Energy 31(2006), pp. 677-693. Cerca con Google

Fang L., Wyon D.P., Clausen G., Fanger P.O., Impact of indoor air temperature and humidity in an office on perceived air quality, Indoor Air, 14(7)(2004), pp. 74-81. Cerca con Google

Fanger P.O., Introduction of the olf and the decipol units to quantify air pollution perceived by humans indoors, Energy and Buildings, 12(1988), pp. 1-6. Cerca con Google

Fokaides P.A., Maxoulis C.N., Panayiotou G.P., Neophytou M.K.-A., Kalogirou S.A., Comparison between measured and calculated energy performance for dwellings in a summer dominant environment, Energy and Buildings, 43(2011), pp. 3099-3105. Cerca con Google

Guan L., Preparation of future weather data to study the impact of climate change on buildings, Buildings and Environment, 44(2009), pp. 793-800. Cerca con Google

Gugliermetti F., Passerini G., BisegnaF., Climate models for the assessment of office buildings energy performance, Building and Environment, 39(2004), pp. 39–50. Cerca con Google

Haghighat F., Donnini G., Impact of psycho-social factors on perception of the indoor air environment studies in 12 office buildings, Building and Environment, 34(4)(1999), pp. 479-503. Cerca con Google

Healy W.M., Lessons learned in wireless monitoring, Building and Fire Research Laboratory National Institute of Standards and Technology, Gaithersburg, ASHRAE Journal, 47(10)(2005). Cerca con Google

Hernandez P., Burke K., Lewis O., Development of energy performance benchmarks and building energy ratings for no-domestic building, an example for Irish primary schools, Energy and Buildings, 40 (2008), pp. 249-254. Cerca con Google

Kalogirou S.A., Applications of artificial neural-networks for energy systems, Applied Energy, 67(1–2)(2000), pp. 17–35. Cerca con Google

Kwak Y., Seo D., Jang C., Huh J., Feasibility study on a novel methodology for short-term real-time energy demand prediction using weather forecasting data, Energy and Buildings, 57(2013), pp. 250-260. Cerca con Google

Menzel K., Pesch D., O’Flynn B., Keane M., O’Mathuna C., Towards a wireless sensor platform for energy efficient building operation, Tsinghua Science and Technology, 13(2008), pp. 381-386. Cerca con Google

Neto A.H., Fiorelli F.A.S., Comparison between detailed model simulation and artificial neural network for forecasting building energy consumption, Energy and Buildings, 40(2008), pp. 2169-2176. Cerca con Google

Nguyen T.A., Aiello M., Energy intelligent buildings based on user activity: a survey, Energy and Buildings, 56(2013), pp. 244-257. Cerca con Google

Nicol J.F., Humphreys M.A., Adaptive thermal comfort and sustainable thermal standards for buildings, Energy and Buildings, 34(6)(2002), pp. 563-572. Cerca con Google

Nicol J.F., Humphreys M.A., Derivation of the adaptive equations for thermal comfort in free-running buildings in European standard EN15251, Building and Environment, 45(1)(2010), pp. 11-17. Cerca con Google

Page J., Robinson D., Morel N., Scartezzini J.L., A generalised stochastic model for the simulation of occupant presence, Energy and Buildings, 40(2)(2008), pp. 83-98. Cerca con Google

P´erez-Lombard L., Ortiz J., Pout C., A review on buildings energy consumption information, Energy and Buildings 40(3)(2008), pp. 394-398. Cerca con Google

Rijal H.B., Tuohy P., Humphreys M.A., Nicol J.F., Samuel A., Clarke J, Using results from field surveys to predict the effect of open windows on thermal comfort and energy use in buildings, Energy and Buildings, 39(2007), pp. 823-836. Cerca con Google

Tronchin L., Fabbri K., Energy performance building evaluation in Mediterranean countries: comparison between software simulation and operating rating simulation, Energy and Buildings, 40(2008), pp. 1176-1187. Cerca con Google

van der Linden A.C., Boerstra A.C., Raue A.K., Kurvers S.R., de Dear R.J., Adaptive temperature limits: a new guideline in the Netherlands. A new approach for the assessment of building performance with respect to thermal indoor climate, Energy and Buildings, 38(1)(2006), pp. 8-17. Cerca con Google

Wargocki P., Wyon D.P., Fanger P.O., Productivity is affected by the air quality in offices, Healthy Buildings, 1(2000), pp. 635-640. Cerca con Google

Wargocki P., Wyon D.P., Baik Y.K., Clausen G., Fanger P.O., Perceived air quality, sick building syndrome (SBS) symptoms and productivity in an office with two different pollution loads, Indoor Air, 9(3)(2009), pp. 165-79. Cerca con Google

Wong L.T., Mui K.W., Hui P.S., A multivariate-logistic model for acceptance of indoor environmental quality (IEQ) in offices, Building and Environment, 43(1)(2008), pp. 1-6. Cerca con Google

Wong S.L., Wan K.K.W., Li D.H.W., Lam J.C., Impact of climate change on residential building envelope cooling loads in subtropical climates, Energy and Buildings, 42(2010), pp. 2098-2103. Cerca con Google

Wyon D.P., The effects of indoor air quality (IAQ) on performance and productivity, Indoor Air, 14(2004), pp. 92-101. Cerca con Google

Yezioro A., Dong B., Leitec F., An applied artificial intelligence approach towards assessing building performance simulation tools, Energy and Buildings, 40(2008), pp. 612-620. Cerca con Google

Zagreus L., Huizenga C., Arens E., Lehrer D., Listening to the occupants: a web-based indoor environmental quality survey, Indoor Air; 14(8)(2004), pp. 65-74. Cerca con Google

Zmeureanu R., Renaud G., Estimation of potential impact of climate change on the heating energy use of existing houses, Energy Policy, 36(2008), pp. 303-310. Cerca con Google

Articoli all’interno di convegni Cerca con Google

Antonucci D.F., Cadorin M., Zecchin R., Monitorare il sistema edificio-impianto: metodologie e aspetti applicativi, AICARR, 2012. Cerca con Google

Apte M.G., A review of demand controlled ventilation, Healthy Buildings, 2006. Cerca con Google

Baldassa P., De Carli M., Scarpa M., Applicazione degli strumenti di calcolo per la diagnosi energetica degli edifici, AICARR, 2009. Cerca con Google

Burke K., Kenny P., Finn D., The transparency and repeatability of building energy performance certification, Dynastee, 2005. Cerca con Google

Corgnati S.P., Filippi M., Cerutti A.A., Rollino L., Energy performance of Italian existing residential buildings: results from asset and operation rating investigations, EERB-BEPH (CHN), 2009. Cerca con Google

EIA, Annual Energy Review 2010, The World Business Council for Sustainable Development, 2011. Cerca con Google

Estrin D., Sayeed A., Srivastava M., Tutorial “Wireless sensor networks”, Atlanta, Georgia, USA, 2002. Cerca con Google

Fabi V., Andersen R.V., Corgnati S.P., Olesen B.W., Filippi M., Description of occupant behaviour in building energy simulation: state-of-art and concepts for their improvement, Building Simulation, 2011. Cerca con Google

Fabrizio E., Branciforti V., Confronto tra asset rating e tailored rating nella riqualificazione energetica di una costruzione forestale in alta quota, ATI, 2010. Cerca con Google

Grigg P., Slater A., Assessment of energy efficiency impact of building regulations compliance report, Energy Efficiency Partnership for Homes, 2004. Cerca con Google

Huizenga C., Laeser K., Arens E., A web-based occupant satisfaction survey for benchmarking building quality, Indoor Air, 2002. Cerca con Google

Milone A., Milone D., Pitruzzella S., Asset rating: disagreement between the results obtained from software for energy certification, IBPSA, 2009. Cerca con Google

Peretti C., Schiavon S., Goins J., Arens E., De Carli M., Evaluation of indoor environment quality with a web-based occupant satisfaction survey: a case study in northern Italy, Clima, 2010. Cerca con Google

Scarpa M., Pasqualetto M., De Carli M., La previsione in tempo reale del comportamento del sistema edificio-impianto: verifica sperimentale, AICARR, 2012. Cerca con Google

WBCSD, Transforming the Market: Energy Efficiency in Buildings, The World Business Council for Sustainable Development, 2009. Cerca con Google

Libri e tesi Cerca con Google

Amadio A., Value Supply Flow. La strategia del flusso valore in un contest supply chain oriented, Franco Angeli, ISBN 9788856847970, 2012, pp. 139-141. Cerca con Google

Beltrame M., Sviluppo di una rete wireless di sensori per il monitoraggio di strutture in tempo reale, Tesi di Laurea, Università degli Studi di Pavia, Facoltà di Ingegneria, Corso di Laurea Specialistica in Ingegneria Informatica, 2007/08. Cerca con Google

Bloem J.J. et al., System identification applied to building performance data, Joint Research Centre, European Commission, Brussels, (1994), pp. 234-236. Cerca con Google

Clarke J.A., Energy Simulation in Building Design (2nd edition), Butterworth Heinemann, ISBN 978-0-7506-5082-3, 2001. Cerca con Google

Crepaldi R., Algoritmi di localizzazione per reti di sensori: progettazione e realizzazione di una piattaforma sperimentale, PhD thesis, Università degli Studi di Padova, Dipartimento di Ingegneria dell’Informazione, 2006. Cerca con Google

DOE (U.S. Department of Energy), Getting Started with EnergyPlus: Basic Concepts Manual-Essential Information You Need About Running EnergyPlus, Berkeley National Laboratory, 2010. Cerca con Google

Ellis A.K., Teaching and Learning Elementary Social Studies, Prentice Hall College, Pearson, ISBN 0137039492, 2010, p. 43. Cerca con Google

Fanger P.O., Thermal comfort. Analysis and applications in environmental engineering, McGraw-Hill, New York, 1970. Cerca con Google

Hand J W., Removing barriers to the use of simulation in the building design professions, PhD Thesis, ESRU - University of Strathclyde in Glasgow, 1998. Cerca con Google

Landi S., Progetto di servizi resource-aware per reti ad-hoc, PhD thesis, Università degli Studi di Bologna, Facoltà di Ingegneria, 2004. Cerca con Google

LBNL (US DOE), Getting Started with EnergyPlus, Berkeley (CA), USA, 2011. Cerca con Google

Libro verde della Commissione, Una strategia europea per un'energia sostenibile, competitiva e sicura, Bruxelles, ISBN 92-79-00017-9, 2005. Cerca con Google

Michielan D., Il processo di previsione della domanda, Tesi di Laurea, Università degli Studi di Udine, Dipartimento di Ingegneria Elettrica, Gestionale e Meccanica, 2002. Cerca con Google

Mills E., Friedman H., Powell T. Bourassa N., Claridge D., Haasl T., Piette M.A., The cost-effictiveness of commercial-buildings commissioning: a meta-analysis of energy and non-energy impacts in existing buildings and new construction in the United States, Lawrence Berkeley National Laboratory Report No. 56637, 2004. Cerca con Google

United Nations Environment Programme, Buildings and Climate Change Status, Challenges and Opportunities, United Nations Environment Programme, Paris, ISBN 9789280727951, 2007. Cerca con Google

VIM, International Vocabulary of Basic and General Terms in Metrology, second edition, Geneva, 1993. Cerca con Google

Riferimenti normativi Cerca con Google

D.G. 31/10/2007 n.8/5773, Certificazione energetica degli edifici, modifiche ed integrazione alla Dgr n. 5018/2007. Cerca con Google

Dgr 26/6/2007 n.8/5018, Determinazioni inerenti la certificazione energetica degli edifici, in attuazione del Dlgs 192/2005 e degli articoli 9 e 25 della I.R. 24/2006. Cerca con Google

EN ISO 13790:2008, Energy performance of building – calculation of energy use for space heating and cooling. Cerca con Google

I.R. 11/12/2006 n.24, Norma per la prevenzione e la riduzione delle emissioni in atmosfera a tutela della salute e dell’ambiente. Cerca con Google

UNI 4546:1984, Misure e misurazioni - Termini e definizioni fondamentali. Cerca con Google

UNI 10349:1994, Riscaldamento e raffrescamento degli edifici – Dati climatici. Cerca con Google

UNI EN 15241:2008, Ventilazione degli edifici - Metodi di calcolo delle perdite di energia dovute alla ventilazione e alle infiltrazioni negli edifici. Cerca con Google

UNI EN 15243:2008, Ventilazione degli edifici - Calcolo delle temperature dei locali, del carico termico e dell’energia per edifici dotati di impianto di climatizzazione degli ambienti. Cerca con Google

UNI EN 15251:2007, Indoor environmental input parameters for design and assessment of energy performance of buildings addressing indoor air quality, Thermal Environment, Lighting and Acoustics. Cerca con Google

UNI EN 15316-4-8:2011, Impianti di riscaldamento degli edifici - Metodo per il calcolo dei requisiti energetici e dei rendimenti dell’impianto - Parte 4-8: Sistemi di generazione per il riscaldamento degli ambienti, riscaldamento ad aria e sistemi di riscaldamento radianti. Cerca con Google

UNI EN 15603:2008, Prestazione energetica degli edifici - Consumo energetico globale e definizione dei metodi di valutazione energetica. Cerca con Google

UNI EN ISO 7730:2006, Ambienti termici moderati. Determinazione degli indici PMV e PPD e specifica delle condizioni di benessere termico. Cerca con Google

UNI EN ISO 9920: 2009, Ergonomia dell'ambiente termico - Valutazione dell'isolamento termico e della resistenza evaporativa dell'abbigliamento. Cerca con Google

UNI EN ISO 15927-4:2005, Prestazione termoigrometrica degli edifici-Calcolo e presentazione dei dati climatici - Parte 4: Dati orari per la valutazione del fabbisogno annuale di energia per il riscaldamento e il raffrescamento. Cerca con Google

UNI/TS 11300-1:2008, Determinazione del fabbisogno di energia termica dell’edificio per la climatizzazione estiva ed invernale. Cerca con Google

Sitografia Cerca con Google

ARPA Veneto, Cerca con Google

<http://www.arpa.veneto.it/bollettini/htm/dati_meteo.asp>. Vai! Cerca con Google

Caprioli C., Analisi delle serie storiche: Strumenti econometrici utilizzati in finanza, <http://classewiki.pbworks.com/w/file/fetch/51865868/Levine11.pdf>. Vai! Cerca con Google

Cenedese A., National research, SIMEA, <http://automatica.dei.unipd.it/people/cenedese/research/simea.html>. Vai! Cerca con Google

Giusti E., Lezione di Ecologia Applicata, 2011, <http://www.dsi.unifi.it/~giusti/Lezione_EcologiaApplicata/1bis_MODELLI_ely>. Vai! Cerca con Google

Marsili S.L., Analisi dei sistemi ambientali, 2010/11, <http://dsii.dsi.unifi.it/~marsili/PPT/7_Modelli_Fuzzy.pdf>. Vai! Cerca con Google

National Instruments Italia, Cerca con Google

<http://www.ni.com/white-paper/8939/it>. Vai! Cerca con Google

Treccani.it, L’enciclopedia Italiana, Cerca con Google

<http://www.treccani.it>. Vai! Cerca con Google

Società per la divulgazione e produzione di energia pulita, Provincia di Vicenza, <http://www.vienergia.it/a_22_IT_70_1.html>. Vai! Cerca con Google

Download statistics

Solo per lo Staff dell Archivio: Modifica questo record