Go to the content. | Move to the navigation | Go to the site search | Go to the menu | Contacts | Accessibility

| Create Account

Taffarel, Sabrina (2016) Metodi speditivi per la valutazione della vulnerabilitĂ  sismica del costruito storico: approccio all'incertezza nelle forme di aggregazione complessa a diversa scala. [Ph.D. thesis]

Full text disponibile come:

[img]PDF Document (Tesi_dottorato_Taffarel_Sabrina)
Thesis not accessible until 31 January 2020 for intellectual property related reasons.
Visibile to: nobody

18Mb

Abstract (english)

The prediction of the impact an earthquake could have on existing buildings requires the knowledge of their dynamic behaviour. The procedure to be adopted for this purpose is quite complex and onerous in terms of costs, time and implementation, especially if the study concerns territorial areas rather than single buildings. The definition of methodologies aimed at respecting the principles of economic sustainability and preserving human life and architectural heritage is of paramount importance to assess seismic vulnerability using available resources.
This work aims at developing useful procedures for uncertainties reduction and reliability assessment of available information, a key phase in the study of aggregate buildings at different scales and particularly of existing masonry structures.
For this purpose, vulnerability studies cannot ignore building knowledge and the consequent achieved level of information, which is closely related to the scale of analysis. The increase of the latter entails the decrease of accuracy and quality (reliability) of available data, which are often uncertain. At the same time, it is not economically viable to fill these gaps using traditional approaches which require the execution of complete on-site surveys. The aims of this research thesis are to maximize the benefits deriving from the analysis of available building information and to give a contribution to the advancement of existing seismic vulnerability approaches, adopting either parametric or probabilistic procedures. Data collection and analysis are implemented in databases and geographic information systems aimed at processing already available data, recorded for different purposes. Procedures for assessing seismic vulnerability on an urban scale are defined adopting mechanical approaches on an analytical basis (fragility curves), in which data uncertainty is overcome through the use of deterministic (parametric) or probabilistic (definition of unknown data from certain ones) approaches. An in-depth analysis at a more detailed scale is also provided: the aim, in this case, is to identify suitable methods to represent the boundary conditions of aggregate building portions to be adopted in seismic analysis in a simplified way. The whole methodological process is then applied to several case studies characterized by different morphology, typology and seismicity (Timisoara (RO) historical centre, small historical centres in L’Aquila province –IT-, listed buildings in Verona, Vicenza and Rovigo provinces –IT-, churches damaged by the 2012 earthquakes in Emilia Romagna and Veneto regions –IT-) selected in order to validate and calibrate the implemented procedures on heterogeneous contexts.

Abstract (italian)

La previsione dell’impatto causato da un evento sismico in termini di effetti sulle costruzioni esistenti in una data area richiede la conoscenza del comportamento dinamico che tali strutture possono manifestare. La procedura da adottare risulta particolarmente complessa e ancor più onerosa in termini economici, di tempo e operativi, se lo studio è riferito a interi complessi costruttivi e non a singoli edifici. La definizione di percorsi metodologici che mirino al rispetto del principio di sostenibilità economica, oltre a quello di salvaguardia della vita umana e di preservazione nonché tutela del patrimonio è prerogativa necessaria per uno studio di vulnerabilità sismica adeguato alle risorse disponibili.
Il presente lavoro di tesi si pone l’obiettivo di sviluppare procedure utili alla riduzione e gestione dell’incertezza, oltre alla valutazione dell’affidabilità dell’informazione insita nello studio di forme di aggregazione complessa a diversa scala, con particolare riferimento alle costruzioni esistenti in aggregato in muratura.
A tal fine, lo studio della vulnerabilità non può prescindere dalla conoscenza del costruito, in cui il livello di informazione è strettamente legato all’estensione della scala di analisi. L’aumento della scala si traduce in una diminuzione nel dettaglio e qualità (attendibilità) dei dati disponibili allo studio, che risultano spesso caratterizzati da incertezza. Al contempo, non è economicamente sostenibile perseguire azioni finalizzate a colmare tali lacune attraverso l’adozione di approcci tradizionali, che richiedano l’esecuzione di completi rilievi in sito. L’elaborato di tesi si propone quindi di trarre il massimo profitto dallo studio e dalla messa a sistema di informazioni sul costruito già disponibili, e al contempo di individuare strategie finalizzate a colmare approcci metodologici lacunosi affrontando lo studio da un punto di vista parametrico o probabilistico. Si persegue quindi l’adozione di procedure di analisi dei dati in forma aggregata e di utilizzo di strumenti informativi geografici e database finalizzate all’analisi di informazioni già a disposizione sul costruito ma raccolte con finalità diverse dallo studio di vulnerabilità su scala territoriale. Viene posta l’attenzione alla definizione di procedure per la valutazione della vulnerabilità su ampia scala che adottino approcci meccanici di tipo analitico attraverso curve di fragilità del costruito, in cui l’attenzione sia posta in primis alla gestione dell’incertezza insita nei dati allo studio, superata attraverso l’utilizzo di approcci deterministici (parametrici) o probabilistici (definizione di dati non noti a partire da altri noti). Un approfondimento ad una scala di maggior dettaglio viene inoltre fornito al fine di individuare idonee modalità di rappresentazione semplificata delle condizioni al contorno nell’analisi sismica di porzioni di edificio in contesto aggregato. L’intero percorso proposto è integrato con applicazioni a casi studio diversi per morfologia, tipologia e sismicità (centro storico di Timisoara –RO-, borghi minori in provincia de L’Aquila, beni tutelati presso le provincie di Verona, Vicenza e Rovigo, chiese colpite dagli eventi sismici del 2012 in Emilia Romagna e Veneto) appositamente selezionati al fine di validare e calibrare le procedure adottate su contesti eterogenei.

Aggiungi a RefWorks
EPrint type:Ph.D. thesis
Tutor:Modena, Claudio
Supervisor:da Porto, Francesca and Valluzzi, Maria Rosa
Ph.D. course:Ciclo 29 > Corsi 29 > STORIA, CRITICA E CONSERVAZIONE DEI BENI CULTURALI
Data di deposito della tesi:31 January 2017
Anno di Pubblicazione:31 January 2016
Key Words:valutazione di vulnerabilitĂ  sismica/seismic vulnerability assessment, scala territoriale/territorial scale, edifici storici in aggregato/historical aggregate buildings, approccio all'incertezza/approach to uncertainty
Settori scientifico-disciplinari MIUR:Area 08 - Ingegneria civile e Architettura > ICAR/09 Tecnica delle costruzioni
Area 08 - Ingegneria civile e Architettura > ICAR/19 Restauro
Struttura di riferimento:Dipartimenti > Dipartimento di Ingegneria Civile, Edile e Ambientale
Codice ID:9838
Depositato il:02 Nov 2017 15:45
Simple Metadata
Full Metadata
EndNote Format

Bibliografia

I riferimenti della bibliografia possono essere cercati con Cerca la citazione di AIRE, copiando il titolo dell'articolo (o del libro) e la rivista (se presente) nei campi appositi di "Cerca la Citazione di AIRE".
Le url contenute in alcuni riferimenti sono raggiungibili cliccando sul link alla fine della citazione (Vai!) e tramite Google (Ricerca con Google). Il risultato dipende dalla formattazione della citazione.

AA.VV. Piani di Ricostruzione di Castel del Monte e Santo Stefano di Sessanio. UNIPD, CNR, POLIMI, La Sapienza, 2014b. Cerca con Google

—. Piani di Ricostruzione di Castelvecchio Calvisio e Villa Santa Lucia degli Abruzzi. UNIPD, CNR, POLIMI, La Sapienza, 2014. Cerca con Google

Aitchison, J. «The Statistical Analysis of Compositional Data.» Journal of the Royal Statistical Society, 1982: 139-177. Cerca con Google

Barbat A.H., Carreno M.L., Pujades L.G., Lantada N., Cardona O.D., Marulanda M.C. «Seismic vulnerability and risk evaluation methods for urban areas. A review with application to a pilot area.» Structure and Infrastructure Engineering, 2010: 17-38. Cerca con Google

Beconcini M.L., Croce P., Marsili F., Muzzi M., Rosso E. «Probabilistic reliability assessment of a heritage structure under horizontal loads.» Probabilistic engineering mechanics, 2016: 198-211. Cerca con Google

Benedetti D., Petrini V. «Sulla vulnerabilità sismica degli edifici in muratura: un metodo di valutazione.» L’industria delle Costruzioni, n.149, 1984. Cerca con Google

Bernardini A., Giovinazzi S., Lagomarsino S., Parodi S. «Vulnerabilità e previsione di danno a scala territoriale secondo una metodologia macrosismica coerente con la scala EMS-98.» Convegno A.N.I.D.I.S. Pisa, Italia, 2007. Cerca con Google

Bettiol G., Munari M., Modena C., Gaudini G., Romano F.G. «Attività emergenziali svolte a seguito degli eventi sismici del Maggio 2012 in Veneto.» ANIDIS 2013_L'ingegneria sismica in Italia. Padova, Italia, 2013. Cerca con Google

Boscotrecase L., Piccarreta F. Edifici in muratura in zona sismica. Dario Flaccovio Ed., 2009. Cerca con Google

Breyemann, G.A. Allgemeine Bau-Constructions-Lehre mit besonderer Beziehung auf das Hochbauwesen. Gustav Weise Verlag, Stuttgart, 1868. Cerca con Google

C.S.LL.PP. «Studio propedeutico all'elaborazione di strumenti d'indirizzo per l'applicazione della normativa sismica agli insediamenti storici.» 2012. Cerca con Google

Calvi G.M., Pinho R., Magenes G., Bommer J.J., Restrepo-Velez L.F., Vrowley H. «Development of seismic vulnerability assessment methodologies over the past 30 years.» ISET journal of Earthquake Technology, 2006: 75-104. Cerca con Google

Campostrini, G.P. «Indagini speditive nella prevenzione e riduzione del rischio sismico del patrimonio storico: un approccio Bayesiano (Tesi di Dottorato).» 2014. Cerca con Google

Carniel R., Ceccotti C., Chiarandini A., Grimaz S., Picco E., Riuscetti M. «A definition of seismic vulnerability on a regional scale: the structural typology as a significant parameter.» Bollettino di Geofisica teorica ed Applicata, 2001: 139-157. Cerca con Google

Cattari S., Galasco A., Lagormarsino S., Penna A. «Aspetti critici nell'analisi sismica statica non lineare degli edifici esistenti in muratura.» 2006. Cerca con Google

Cattari S., Ottonelli D., Pinna M., Lagomarsino S., Clark W., Giovinazzi S., Ingham J., Marotta A., Liberatore D., Sorrentino L., Leite J., Lourenco P.B., Goded T. «Preliminary results from damage and vulnerability analysis of URM churches after the Canterbury earthquake sequance 2010-2011.» NZSEE_New Zealand Society for Earthquake Engineering Conference. Rotorua, New Zealand, 2015. Cerca con Google

Circolare 15/2015_Disposizioni in materia di tutela del patrimonio architettonico e mitigazione del rischio sismico. Governo Italiano, s.d. Cerca con Google

Circolare 617/2009 - Istruzioni per l'applicazione delle "Nuove NTC" di cui al D.M. 14/01/2008. Governo Italiano, s.d. Cerca con Google

Cod. de proiectare seismica - Prevederi de proiectare pentru cladiri - Partea I. 2013. Cerca con Google

Crosier S., Booth B., Dalton K., Mitchell A., Clark K. ArcGis 9: getting started with ArcGIS. New York: ESRI, 2005. Cerca con Google

D.LGS. 42/2004 - Codice dei Beni Culturali e del Paesaggio. s.d. Cerca con Google

D.M. 14/01/2008 - Norme Tecniche per le Costruzioni. Governo Italiano. Cerca con Google

D.P.C.M. 09/02/2011 - Linee Guida per la valutazione e riduzione del rischio sismico del patrimonio culturale allineate alle nuove Norme Tecniche per le Costruzioni. Governo Italiano. Cerca con Google

D.P.C.M. 09/02/2011 - Valutazione e riduzione del rischio sismico del patrimonio culturale con riferimento alle nuove Norme Tecniche per le Costruzioni di cui al DM 14/01/2008. Governo Italiano. Cerca con Google

da Porto F., Munari M., Prota A., Modena C. «Analysis and repair of clustered buildings: Case study of a block in the historic.» Construction and Building Materials, 2013: 1221-1237. Cerca con Google

da Porto F., Silva B., Costa C., Modena C. «Macro-scale analysis of damage to churches after earthquake in Abruzzo (Italy) on April 6, 2009.» Journal of earthquake engineering, 2012: 739-758. Cerca con Google

DCT, R Development Core Team. R: A language and environment for statistical computing. R Foundation for Statistical Computing, Vienna, Austria, 2008. Cerca con Google

Dell'Orto C., Guzzetti F., Maroldi F., Molina C. «G.I.S. per la valutazione dei danni post-sisma. il caso del centro storico di Fontecchio.» Convegno sul recupero e la conservazione . Venezia, Italia, 2010. Cerca con Google

Dolce, M. «Politiche di prevenzione del rischio sismico a scala nazionale.» Dossier Urbanistica, maggio 2013: 3-4. Cerca con Google

Dong L., Shan J. «A comprehensive review of earthquake induced building damage detection with remote sensing techniques.» ISPRS Journal of Photogrammetry and Remote Sensing n. 84, 2013: 85-99. Cerca con Google

DPC-ReLUIS-UfficioViceCommissario-STM. «Linee Guida per il Rilievo, l'Analisi ed il Progetto di Interventi di Riparazione e Consolidamento Sismico di Edifici in Muratura in Aggregato (Bozza - Ottobre 2010).» 2010. Cerca con Google

«EN 1998-1:2010 - Eurocode 8 - Design of structures for earthquake resistance.» Cerca con Google

Fabris M., Achilli V., Campostrini G.P., Modena C. «L’aerofotogrammetria digitale per la stima delle caratteri-stiche strutturali degli edifici.» ANIDIS 2013_XV Convegno - L'ingegneria Sismica in Italia. Padova, Italia, 2013. Cerca con Google

Fajfar, P. «A nonlinear analysis method for performance based seismic design.» Earthquake spectra, 2000: 573-592. Cerca con Google

FEMA. HAZUS Earthquake Loss Estimation Methodology. Technical Manual. Federal Management Agency USA, 1999. Cerca con Google

Formisano A., Florio G., Landolfo R., Mazzolani F.M. «Un metodo per la valutazione su larga scala della vulnerabilità sismica degli aggregati storici.» ANIDIS. Bari, Italia, 2011. Cerca con Google

Formisano A., Marzo A., Marghella G., Indirli M. «Seismic vulnerability assessment methods applied to the historic built-up of Arsita within the 2009 post-earthquake reconstruction plan.» International Journal of Sustainable Materials and Structural Systems, 2016. Cerca con Google

Gamerman D., Lopes H. F. Markov Chain Monte Carlo: Stochastic Simulation for Bayesian Inference. Chapman & Hall/CRC, 2006. Cerca con Google

Garlasco A., Frumento S. Analisi sismica delle strutture murarie. Calcoli strutturali. Sistemi Editoriali. Cerca con Google

Giovinazzi S., Lagomarsino S. «A macroseismic method for the vulnerability assessment of buildings.» 13th World Conference on Earthquake Engineering. Vancouver, Canada, 2004. Cerca con Google

Giuffrè, A. Sicurezza e conservazione dei centri storici: il caso Ortigia. Laterza, 1993. Cerca con Google

Hoff, P.D. A First Course in Bayesian Statistical Methods. Springer, 2009. Cerca con Google

Indirli M., Marghella G., Marzo A. «Damage and collapse mechanisms in churches during the Pianura Padana Emiliana earthquake.» Energia Ambiente Innovazione, 2012: 69-94. Cerca con Google

INFP. Seismicity of Romania. 2013. http://www.infp.ro/localseismicity/romanian-seismicity. Vai! Cerca con Google

Irizarry J., Lantada N., Pujades L.G., Barbat A.H., Goula X., Susagna T., Roca A. «Ground-shaking scenarios and urban risk evaluation of Barcelona using the Risk-UE capacity spectrum based method.» Bulletin of earthquake engineering, 2011: 441-466. Cerca con Google

ISO 31000/2009 - Risk management - Principles and guidelines. International Organization for Standardization. Cerca con Google

ISO/DIS-13824. «General principles on risk assessment of systems involving structures.» 2008. Cerca con Google

ISO-13822. «Bases for design of structures - Assessment of existing structures - Annex I (Informative) Historic structures.» 2001. Cerca con Google

Jackman, S. Bayesian Analysis for the Social Sciences . Wiley, 2009. Cerca con Google

L. 77/2009_Conversione in legge, con modificazioni, del D.L. 28/04/09, n. 39. Cerca con Google

Lagomarsino S., Cattari S. «PERPETUATE guidelines for seismic performance based assessment of cultural heritage masonry structures.» Bulletin of Earthquake Engineering, 2014: 13-47. Cerca con Google

Lagomarsino S., Penna A., Galasco A., Cattari S. «TREMURI program: An equivalent frame model for the non linear seismic analysis of masonry buildings.» Engineering structures, 2013: 1787-1799. Cerca con Google

Lestuzzi P., Podestà S., Luchini C., Garofano A., Kazantzidou-Firtinidou D., Bozzano C., Bischof P., Haffter A., Rouiller J-D. «Seismic vulnerability assessment at urban scale for two typical Swiss cities using Risk-UE methodology.» Natural Hazards, 2016: 249-269. Cerca con Google

Liseo, B. Introduzione alla statistica Bayesiana. Springer ed., 2008. Cerca con Google

Lourenco P.B, Roque J.A. «Simplified indexes for the seismic vulnerability of ancient masonry buildings.» Construction and Building Materials, 2006: 200-208. Cerca con Google

Magenes G., Bolognini D., Braggio C. Metodi semplificati per l’analisi sismica non lineare di edifici in muratura. . Roma: CNR-GNDT, 2000. Cerca con Google

Mazzanti P., Rocca A., Bozzano F., Cossu R., Floris M. «Landslide forecasting analysis by displacement time series derived from satellite inSAR data: preliminary results.» Proceedings of the Fringe 2011 Workshop. Frascati, Roma, 2011. Cerca con Google

MIBACT. «Circolare n.15_Disposizioni in material di tutela del patrimonio architettonico e mitigazione del rischio sismico.» 2015. Cerca con Google

Modena C., da Porto F., Bettiol G., Giaretton M. «Edilizia storica monumentale – Salvaguardia degli edifici di interesse storico-artistico nell’emergenza post-sisma.» Progettazione sismica, 2012: 211-221. Cerca con Google

Modena C., da Porto F., Valluzzi M.R. «Conservazione del patrimonio architettonico e sicurezza strutturale in zona sismica: insegnamenti dalle recenti esperienze italiane.» Materiali e Strutture, 2012: 17-28. Cerca con Google

Modena, C. «Una proposta operativa di approccio sostenibile alla valutazione e mitigazione del rischio sismico dei centri storici.» In I quaderni della Soprintendenza per i beni architettonici e paesaggistici per le province di Verona, Rovigo e Vicenza. 2014. Cerca con Google

Morbin R., Zanini M.A., Pellegrino C., Zhang H., Modena C. «A probabilistic strategy for seismic assessment and FRP retrofitting of existing bridges.» Bulletin of earthquake Engineering, 2015. Cerca con Google

Mosoarca M., Petrus C., Stoian V., Anastasiadis A. «Seismic risk of buildings with RC frames and masonry in-fills from Timisoara, Banat region, Romania.» Proc. 9th International Masonry Conference. Guimaraes, Portugal, 2014. Cerca con Google

Mouroux P., Le Brun B. «Presentation of RISK-UE Project.» Bulletin of Earthquake Engineering, 2006: 323-339. Cerca con Google

Nath S.K., Adhjkari M.D., Devaraj N., Maiti S.K. «Seismic vulnerability and risk assessment of Kolkata City, India.» Natural hazards Earth System Sciences, 2015. Cerca con Google

Oros, E. «Seismicitatea, seismotectonica şi hazardul seismic din zona Timişoara.» Buletinul AGIR 3, 2012. Cerca con Google

Ottonelli D., Cattari S., Lagomarsino S. «Urban risk assessment: fragility functions for masonry buildings.» Recent advances in mechanics, mechatronics and civil, chemical and industrial engineering. Zakynthos Islands, Grecia: Imre J. Rudas & Dora Foti editors, 2015. Cerca con Google

Parodi S., Lagomarsino S., Varum H., Mendes Silva J.A.R. «Seismic vulnerability and risk assessment: case study of the historic city centre of Coimbra, Portugal.» Bulletin of earthquake engineering, 2011: 1067-1096. Cerca con Google

PCM-DPC. CARTIS_Manuale per la compilazione della scheda di 1° Livello per la caratterizzazione tipologico-strutturale dei comparti urbani costituiti da edifici ordinari. A cura di Progetto ReLUIS 2014-2016. 2016. Cerca con Google

PCM-DPC. Manuale per la compilazione della scheda di 1° livello di rilevamento danno, pronto intervento e agibilità per edifici ordinari nell'emergenza post-sismica (AeDES). 2014. Cerca con Google

PCM-DPC. Manuale per la compilazione della Scheda per il rilievo del danno ai beni culturali, Chiese_Modello A-DC. 2011. Cerca con Google

PCM-DPC. Protezione Civile_Descrizione del Rischio sismico. s.d. http://www.protezionecivile.gov.it/jcms/it/descrizione_sismico.wp. Vai! Cerca con Google

PCM-DPC-MIBAC. Modello A-DC_Scheda per il rilievo del danno ai beni culturali - Chiese. 2006. Cerca con Google

PCM-DPC-MIBAC. Modello B-DP_Scheda per il rilievo del danno ai beni culturali - Palazzi. 2006. Cerca con Google

Pittore M., Wieland M. «Toward a rapid probabilistic seismic vulnerability assessment using satellite and ground based remote sensing.» Natural Hazards n. 68, 2013: 115-145. Cerca con Google

Pujades L.G., Barbat A.H., Gonzales-Drigo R., Avila J., Lagomarsino S. «Seismic performance of a block of buildings representative of the typical construction in the Example district in Barcelona (Spain).» Bulletin of Earthquake Engineering, 2012: 331-349. Cerca con Google

Rezaie F., Panahi M. «GIS modeling of seismic vulnerability of residential fabrics considering geotecnical, structural, social and physical distance indicators in Tehran using multi-criteria decision-making techniques.» Natural Hazards Earth System Sciences, 2015: 461-474. Cerca con Google

Rivas-Medina A., Gaspar-Escribano M., Benito B., Bernabè M.A. «The role of GIS in urban seismic risk studies: application to the city of Almeria (southern Spain).» Natural Hazards Earth System Sciences, 2013: 2717-2725. Cerca con Google

Rondelet, J. Traité théorique et pratique de l’art de bâtir. Parigi, Francia, 1802-1817. Cerca con Google

Rota M., Penna A., Magenes G. «A methodology for deriving analytical fragility curves for masonry buildings based on stochastic nonlinear analyses.» Engineering structures, 2010: 1312-1323. Cerca con Google

Rush, A. Seismic evaluation of masonry building conglomerations of adjacent structures. Supervisor: Dr. Magenes, Dr. Penna, 2007. Cerca con Google

Salmaso, M. Analisi di dati in forma aggregata di edifici vincolati dei centri storici ed integrazione in strumenti di pianificazione per la mitigazione del rischio sismico. 2016. Cerca con Google

Senaldi, I. Numerical investigations on the seismic response of masonry building aggregates. Supervisors: Prof. Magenes, Dr. Penna, 2009. Cerca con Google

Shibin L., Lili X., Maosheng G., Ming L. «Performance-based methodology for assessing seismic vulnerability and capacity of buildings.» Earthquake engineering and engineering vibration, 2010: 157-165. Cerca con Google

Shinozuka M., Feng M.Q., Kim H., Kim S.H. «Nonlinear static procedure for fragility curve development.» Journal of Engineering Mechanics-Asce, 2000a: 1287-1295. Cerca con Google

Shinozuka M., Feng M.Q., Lee J., Naganuma T. «Statistical analysis of fragility curves.» Journal of Engineering Mechanics-Asce, 2000b: 1224-1231. Cerca con Google

Silva V., Crowley H., Varum H., Pinho R., Sousa R. «Evaluation of analytical methodologies used to derive vulnerability functions.» Earthquake engineering and structural dynamics, 2014: 181-204. Cerca con Google

Simoes A., Milosevic Jelena, Meireles H., Bento R., Cattari S., Lagomarsno S. «Fragility curves for old masonry building types in Lisbon.» Bulletin of Earthquake Engineering, 2015: 3083-3105. Cerca con Google

Sinha R., Aditya K.S.P., Gupta A. «GIS-based urban seismic risk assessment using RISK.iitb.» ISET Journal of Earthquake Technology, 2008: 41-63. Cerca con Google

Sorrentino L., Liberatore L., DecaniniL.D., Liberatore D. «The performance of churches in the 2012 Emilia earthquakes.» Bulletin of earthquake Engineering, 2014b: 2299-2331. Cerca con Google

Sorrentino, L. «Reconstruction plans after the 2009 L'Aquila earthquake. From building performance to historical centre perfor-mance.» SAHC2014_ 9th International Conference on Structural Analysis of Historical Constructions. Mexico City, Mexico, 2014. Cerca con Google

Taffarel S., Caliman M., Valluzzi M.R., da Porto F., Modena C. «Seismic vulnerability assessment of clustered historical centers: fragility curves based on local collapse mechanisms analyses.» IBMAC 2016_16th International Brick and Block Masonry Conference. Padova, Italy: Taylor and Francis, 2016. 2563-2470. Cerca con Google

Taffarel S., Campostrini G.P., Rosato L., da Porto F., Modena C. «Seismic vulnerability assessment on a territorial scale based on a Bayesian approach.» IBMAC 2016 - Brick and Block Masonry. Trends, innovations and Challenges. Padova: Taylor and Francis Group, London, 2016. 2471-2478. Cerca con Google

Taffarel S., Campostrini G.P., Rosato L., Marson C., da Porto F., Modena C. «The application of a Bayesian approach to assess the seismic vulnerability of historical centers.» SAHC 2016 - 10th International Conference on Structural Analysis of Historical Constructions. Leuven. Belgio, 2016. Cerca con Google

Taffarel S., Giaretton M., da Porto F., Modena C. «Damage and vulnerability assessment of URM buildings after the 2012 Northern Italy earthquakes.» IBMAC 2016_16th International Brick and Block Masonry conference. Padova, Italy, 2016b. Cerca con Google

Taffarel S., Marson C., Valotto C., Roverato M., Munari M., da Porto F., Modena C., Mosoarca M. «Seismic vulnerability maps of Timisoara historical center based on fragility curves.» SAHC 2016_10th International Conference on Structural Analysis of Historical Constructions. Leuven, Belgium, 2016. Cerca con Google

UNESCO. New life for historic cities: the Historic Urban Landscape Approach Explained. Parigi, Francia: UNESCO Publishing, 2013. Cerca con Google

UNESCO. «Recommendation on the Historic Urban landscape.» Records of the General Conference 36th session. 2012. http://unesdoc.unesco.org/images/0021/002150/215084e.pdf#page=52. Vai! Cerca con Google

Valotto C., Taffarel S., Marson C., Munari M., da Porto F., Modena C. «Seismic vulnerability assessment of corner buildings in the historical centre of Timisoara.» IBMAC 2016_16th International Brick and Block Masonry Conference. Padova, Italy: Taylor & Francis Group, 2016. 2499-2506. Cerca con Google

Vicente R., Ferreira T., Maio R. «Seismic Risk at the Urban Scale: Assessment, Mapping and Planning.» Procedia Economics and Finance, 2014: 71-80. Cerca con Google

Vicente R., Ferreira T., Maio R., Valum H., Costa A.A., Costa A., Oliveira C.S., Estevao J. « Seismic vulnerability assessment of existing masonry buildings: case study of the old city centre of Faro, Portugal.» Second European Conferenze on earthquake engineering and seismilogy . Istanbul, Turchia, 2014. Cerca con Google

Vicente R., Ferreira T., Varum H., Costa A., Maio R. «Seismic vulnerability and risk assessment at the scale of the Old City Centre.» Cultural HELP. Porto, Portogallo, 2014. Cerca con Google

Vicente R., Parodi S., Lagomarsino S., Varum H., Mendes da Silva J.A.R. «Seismic vulnerability assessment, damage scenarios and loss estimation. Case study of the old city centre of Coimbra, Portugal.» The 14th World Conference on Earthquake EEngineering. Beijing, China, 2008. Cerca con Google

Solo per lo Staff dell Archivio: Modifica questo record